DETAILS OF OPTIONAL ITEMS FOR NEOCOTA R & D / PILOT MODEL
- Flow measurement of inlet drying air using Differential Pressure Transmitter and Delta Tube
- Humidity and Temperature Sensor for display of humidity and temperature inside the Pan Cabinet.
- Audio visual alarm annunciation when pressure drop across the HEPA Filter exceeds set point
- Display of atomization air pressure and alarm when the atomization air pressure falls below the set point.
- Measurement of actual flow rate of coating solution through use of Mettler Toledo make Load Cell along with S.S. Platform in the Liquid Storage Vessel and solid state electronic controller
- Packed Bed Spray Tower Type Wet Scrubber
- Cartridge type Bag Filer with reverse pulse jet cleaning device
- Display and alarm in HMI for presence of negative pressure in the Pan Cabinet through necessary instruments including Differential Pressure Transmitter
- Automatic motorized Dampers for inlet and exhaust air volume control from HMI
- AC Frequency Drive for Inlet and Exhaust Blower Motors
- Piston Dosing Pump with accessories for sugar coating
- HEPA Filter with Pre-filter in S.S. casing
- Peristaltic Pump Head with Flame-proof Geared Motor and VFD